Multi-Cassette Autoclave | Small Steam Sterilizer for Dental and Ophthalmology Clinics

Multi-Cassette Autoclave | Small Steam Sterilizer for Dental and Ophthalmology Clinics

Multi-Cassette Autoclave | Small Steam Sterilizer for Dental and Ophthalmology Clinics
Multi-Cassette Autoclave | Small Steam Sterilizer for Dental and Ophthalmology ClinicsMulti-Cassette Autoclave | Small Steam Sterilizer for Dental and Ophthalmology ClinicsMulti-Cassette Autoclave | Small Steam Sterilizer for Dental and Ophthalmology ClinicsMulti-Cassette Autoclave | Small Steam Sterilizer for Dental and Ophthalmology Clinics
CategoriesCassette Autoclave
BrandAIKSMED Steam Autoclave Sterilizer Manufacturer
ModelCeler2000S1/2/3, Celer5000S1/2/3, Celer6000S1/2/3
Cassette Volume2L, 5L, 6L
Control SystemTouch Screen
Cassetteone/two/three levels
Lead Time7 working days
Terms of PaymentT/T
Download DOCpdf icon
Update TimeApr 20,2024
Detail Information
Apply:
Multi-Cassette Autoclave mainly used for sterilization of Dental, Ophthalmic, and Gynecological Instruments, Endoscope and other small Surgical Instruments.
Cassette Autoclave Dental Clinics
Cassette Autoclave Dental Clinics
Features:
1. Efficient:
   The shortest unwrapped cycle: 6~8 minutes,wrapped cycle: 10~15 minutes.
    All Cassettes sterilized together or independently.
2. Easy:
    Choose cycle, and start it, so easy!
3. Small:
    Compact in structure, can be placed up or down the table.
4. Safe:
    Safety valve guarantees operation.
5. Smart:
    Data can be saved and traced back!
6. Gentle:
    Steam is injected by positive pressured pulses, safe and gentle on expensive instruments.
7. Reliable:
    Low failure rate based over 15 years' experience and customer feedback.
   

Cassette Autoclave working principle
Working Principle
Steam generated by built-in vapor is injected into the cassette to remove cold air.
Cycle
Sterilize Temp.
Sterilize Time
Dry Time
Positive Pulse
Rapid ( Unwrapped N )
134℃
240S
900S
1
General ( Wrapped S )
134℃
240S
3600S
3
Porous ( Unwrapped S )
134℃
600S
900S
3
Low Temp.( Wrapped S)
121℃
1800S
900S
3
Self-define ( Mixed )
134℃
900S
900S
6
Air Dry ( Auxiliary )
---
---
900S
---
Cassette Autoclave

Model
Celer2000
Celer5000
Celer6000
S1
S2
S3
S1
S2
S3
S1
S2
S3
Length
615
Width
320
Height
320
470
620
320
470
620
320
470
620
N/W
27
41
55
33
54
75
33
54
75
KVA
1.3
2.6
3.9
1.3
2.6
3.9
1.3
2.6
3.9
Cassette
Size

390*196*40mm

480*196*80mm

570*196*80mm
Cassette
Volume

1.8L

5.2L

6.0L
Working
Temp.

115~134℃
Power
AC220V±22V, 50Hz±1Hz