Cutomized BIER Indicator Evaluation Resistometer for Biological Indicator | BIER | CIER, 3L, 5L

Cutomized BIER Indicator Evaluation Resistometer for Biological Indicator | BIER | CIER, 3L, 5L

Cutomized BIER Indicator Evaluation Resistometer for Biological Indicator | BIER | CIER, 3L, 5L
Cutomized BIER Indicator Evaluation Resistometer for Biological Indicator | BIER | CIER, 3L, 5LCutomized BIER Indicator Evaluation Resistometer for Biological Indicator | BIER | CIER, 3L, 5LCutomized BIER Indicator Evaluation Resistometer for Biological Indicator | BIER | CIER, 3L, 5LCutomized BIER Indicator Evaluation Resistometer for Biological Indicator | BIER | CIER, 3L, 5LCutomized BIER Indicator Evaluation Resistometer for Biological Indicator | BIER | CIER, 3L, 5L
CategoriesBiological Indicator BIER 3L, 5L
BrandAIKSMED Steam Autoclave Sterilizer Manufacturer
ModelKLY-03, KLY-05
ApplySteam Sterilization Chemical Indicator Card
Chamber Volume3L, 5L
Chamber SizeΦ125*250, Φ150*250
Open-door MethodHorizontal Quick-opening
Design Pressure0.4MPa
Working Temperature110~145℃
Electricity380±38V, 50±1Hz,5.5KVA
Vacuum Degree-96KPa
Terms of PaymentT/T
Download DOCpdf icon
Update TimeApr 20,2024
Detail Information

Cutomized BIER Indicator Evaluation Resistometer BIER/CIER Indicator Resistometer is a vessel to evaluate the resistance of biological or chemical indicators to sterilization, and to test the amount of bacteria contained in the pressure steam sterilization biological indicator, and the survival time, killing time and D value under the action of 121℃±0.5℃ saturated steam were determined.
BIER Resistometer Indicator
BIER Resistometer Indicator
Standard for Microbial Content and Resistance of Biological Indicators

1) Bacillus stearothermophilus ATCC 7953 or SSI K31. The amount of bacteria recovered was 5×105cfu/ piece ~ 5×106cfu/ piece, or 5×105cfu/ml ~ 5×106cfu/ml.

2) Under the condition of 121℃±0.5℃ saturated steam, survival time ≥3.9min, killing time ≤19min.

3) Under the condition of 121℃±0.5℃ saturated steam, D value is 1.3min ~ 1.9min.
Item
Parameters
Model
KLY-3/5
Design Pressure
-1~0.4MPa
Working Pressure
-98~350KPa
Working Media
Distilled Water/Pure Water
Water Tank Volume
20L
Chamber Size
Φ125×280mm
Working Volume
3L/5L
Machine Dimension
W700*H1700*D1000mm
Net Weight
300kg